The IsoCap-V1HP module is designed to isolate and scale low voltages found in industrial enviroments. The end result connects to any data acquisition system.
Output voltage:±10V, ±5V Bandwidth (-3dB point):5kHz Max Input delay:<3μsInput ranges | ± 50 mV, ± 100 mV, 150 mV, ± 300 mV, ± 400 mV, 500 mV, ± 750 mV, |
Input-Output non-linearity | < 0.08 % |
Output voltage | ± 10 V (Differential), ± 5 V, ± 2.5 V |
Isolation voltage | ± 50 ppm / °C |
Power Supply Voltage | 12 V to 36 V |
Output type | Differential pair or Single-Ended |
Output Offset Voltage | 2σ < ± 500 μV (typical) 4σ < ± 1 mV (limit) |
Output impedance | 100 Ω (Differential), 50 Ω (Single-Ended) |
Insulation impedance | > 10 GΩ || 2 pF |
Differential Input impedance | > 1 MΩ |
Operating temperature | – 25 to 70 °C |
Storage temperature | – 40 to 70 °C |
Mounting Type | DIN Rail |
The IsoCap-V1HP has been designed to provide high-quality isolated differential voltage measurements for aplications requiring scaling of low voltages, as well as superior isolation. The input has its own isolated reference, and can be configured to suit user needs. The output signal from the IsoCap unit is referenced in respect to the ground channel of the user’s data acquisition system. Designs its IsoCap-V1HP modules with consideration for user great flexibility, and low power consumption.
Accuracy | ± (1 % of reading + 0.005 % range) |
Max total phase shift at 50Hz | < 0.05° |
Max Input delay | < 3 μs |
Isolation voltage from primary to secondary | > ± 1500 V |
Withstanding common mode surge voltage (1min) | ± 5000 V |
Bandwidth (-3dB point) | 5 kHz |
The IsoCap-V1HP module is designed to isolate and scale low voltages found in industrial enviroments. The end result connects to any data acquisition system.
The IsoCap-V1HP's signal input has surge protection circuitry, the operation amplifier converts the input signal to ±10V range, The modulator converts this analog input signal into a digital bitstream that is transferred across the isolation barrier. On the low-side, the received bitstream is processed by a fourth-order analog filter that outputs a differential signal. The operation amplifier with an anti-aliasing filter outputs ± 10V. The following diagram depicts the signal processing above.
- The isolation barrier of every device is tested with a 5 second partial discharge of 1800V for 5 seconds, with a detection threshold of 150pC.
- Withstanding common mode surge voltage is 2 seconds half sinewave.
- Withstanding differential mode surge voltage is 4 seconds half sinewave.